DOCUMENT NO: ASAP 5009 VERSION: 2010-10-25 Page 1 of  8 

TITLE:  Application Procedure for Acceptance of Conduit Hose, Fire Suppression 

      Hose and Fire Hose Liner for Use in Underground Coal Mines 

MSHA  Mine Safety and Health Administration, Approval & Certification Center


1.0  PURPOSE 

This document establishes the Mine Safety and Health Administration’s (MSHA) 

Standard Application Procedure (SAP) for the acceptance of Hose Conduit, Fire 

Hose Liner and Fire Suppression Hose under 30 CFR, Part 18. 

2.0  SCOPE 

These procedures apply to all applications for acceptances of Hose Conduit, Fire 

Hose Liner and Fire Suppression Hose under 30 CFR, Part 18. 

3.0  REFERENCES 

3.1.Approval and Certification Center (A&CC) Cancellation Policy (APOL 

1009). 

3.2.Code of Federal Regulations (30CFR) Parts 18.65, 75.1100-1(f)(1) and 

75.1107-13(c). 

4.0  DEFINITIONS 

4.1.Fire Hose Liner:  The innermost tube of a fire hose. 

4.2.Fire Suppression Hose:  A hose used on a fire suppression device. 

4.3.Hose Conduit:  A protective hose used over electrical cables.  Hose conduit 

is not to be split. 

5.0  APPLICATION PROCEDURE 

5.1.It is recommended that applicants contact the Quality Assurance & 

Materials Safety Division at 304-547-0400 to discuss acceptance and testing 

requirements prior to submitting an application. 

5.2.The application requesting an acceptance or extension of acceptance should 

be sent to the following address: 

MSHA, Approval and Certification Center 

Attention: IPSO 

765 Technology Drive 

Triadelphia, West Virginia  26059 

a.FAX to:  304-547-2084 

b.Email Submittals: 

c.Application letters, specifications, drawings and other supporting 

documentation should be sent to zzMSHA-IPSO@DOL.gov 

d.FTP Submittals: 

e.Application letters and supporting documentation can be placed on the MSHA FTP server, mfgr.msha.gov. 

 Please call the Information Processing Services Office (IPSO) at 304-547-0400 to establish your user account. 

5.2.1.Each application for acceptance of a product must be in the English Language and include the following

 information on the attached application form (Attachment 1, Item 1). 

a.Company name 

b.Address 

c.Telephone & FAX number of company representative 

d.Company representative name 

5.2.2.A 6 digit or less numeric code (Application Code) assigned by the applicant (Attachment 1, Item 2).


5.2.3.Identify if the application request is for a new acceptance or an extension of an existing acceptance 

number (Attachment 1, Item 3). 

5.2.4.Identify and describe the product (as applicable) on Attachment 1, Item 4.  Additional information and

 any special information should be attached. 

5.2.5.Provide information on the compounds in the product:  Each ingredient must be specified by its

 chemical or generic name along with its percentage (weight) and tolerance (Attachment 2, Item 5).  

Organic ingredients should be named according to the current rules of the International Union of Pure

 and Applied Chemistry.  Inorganic ingredients should be named according to the Chemical Abstract 

of the American Chemical Society.  A prepolymer formulation which has been registered with MSHA 

may be identified by furnishing the MSHA assigned ID number.  However, each additional ingredient

the manufacturer adds to the chemical or generic name, along with its percentage (weight) and tolerance

 must be identified by chemical or generic name, along with its percentage (weight) and tolerance. 

 Use one of the methods listed below in 5.2.5.1, 5.2.5.2 or 5.2.5.3 (Attachment 1, Item 5). 

5.2.5.1.Specify each ingredient by its chemical name along with its percentage (weight) and tolerance 

or percentage range.  Organic ingredients should be named according to the current rules of the

 International Union of Pure and Applied Chemistry.  Inorganic ingredients should be named according

 to the Chemical Abstract of the American Chemical Society. 

5.2.5.2.Specify each fire retardant ingredient by its chemical or generic name with its percentage and

 tolerance or percentage range or its minimum percent.  List each flammable ingredient by chemical, 

generic, or trade name along with the TOTAL percentage of all flammable ingredients.  List each

 inert ingredient by chemical, generic, or trade name along with the TOTAL percentage of all inert

 ingredients.  In addition, the product formulation with percentages and tolerances should be kept

 on file by the applicant.  The formulation shall be available to MSHA at the applicant’s premises

 upon request should a product be involved in a mine accident, incident, or quality assurance check. 

5.2.5.3.Specify each fire retardant ingredient by its chemical or generic name with its percentage and

 tolerance or percentage range or its minimum percent.  List all other ingredients.  A flame test 

quality assurance program subject to acceptance by the Approval and Certification Center, Quality

 Assurance and Materials Testing Division should also be provided to maintain the accepted flame

 resistance level of the product.  

The flame test program should be maintained and documented as long as the product is made and

 acceptance is in effect.  The flame test records should be available for examination by MSHA personnel.  

In addition, the product formulation with percentages and tolerances should be available to MSHA at 

the applicant’s premises upon request should a product be involved in a mine accident, incident, or

 quality assurance check.